My guesses are that it allows only a maximum of 2A and/or 250V through, anything more will cause it to cut off to prevent any damage to the appliance. Or you can ask your friend for help If you can not pay via paypal, we can cancel this transaction for you. But, if the voltage is too high, there may be some current flowing through parasitic capacitance. Cablesgo provides United Kingdom Power Cord and Power Supply Cord Sets 3A,5A,13A Fuse 250V BS 1363A AC Type G Plug products and UK plug,socket standard approvals, production drawings and technical support,Buying UK molded plug power cord , contact Cablesgo, China well-known power cord manufacturer. 4kW Ditto 5A will work up to 1. European Schuko Plug To UK Converter Plug WITH Earth Contact, 13A, Black. A wireless waterproof 13A RC outdoor remote control switch box. Get your trade card and buy online & in-branch today! There’s no need to wait for your trade card to turn up. I can use the kettle on another circuit with no problem. These fuses are opaque and often contain sand which is use to prevent a conductive film from forming on the fuse. If you were to put a 13A fuse instead of a 3A and the appliance was to develop a short circuit (extreme condition I know!), then 13A of current would be drawn through the cable causing it to heat up and possibly catch fire! The fuse is put in to be a 'weak link' to ensure that the fuse burns out before the cable does. I will check and see if any of the other wires from j115 are going to higher rated fuses. My question is, do I need to wire the new oven through the 13A fused spur again or can I remove that entirely and safely wire the oven directly to the 45A fused cooker isolator/ switch. This has a 45A fuse for the cooker isolator. The power cable plugs into a box which then plugs into the VGA cable in the back of the tower (emachines). Best Answer: None. Some are 3A some 5A. The way fuses work is there are a length of thin wire designed to break or trip at a certain power level i. A client has asked if i can install single 13a sockets instead of 5a sockets for the sitting room lighting. This web page will define common fuse ratings using either a 3, 5 or 13 amp fuse. Buy Cooper Bussmann, 13A Ceramic Cartridge Fuse, 6. 'Posi-Fit' plug connection is a vibration proof fitting, used for those off road conditions or to connect your Engel to your 12/24 volt system. Copper Plug 100- 250V 13A USA EU to UK Plug with Fuse, US $ 0. Fuse or circuit breakers, are devices that protect your electronic equipments(ee) from getting damaged by a surge that has a current more than what ee could. com, it just take a few minutes. The plug got very hot after 3 minutes. Afaict all BS546 fused plugs use BS646 fuses so there is nothing stopping someone fitting a 5A fuse to a 2A plug. 5A for 4 hours before blowing, or 5A to instantly blow. UK 13A Plugs (BS1363 Plug) Although all appliances sold in the UK today are supplied with fitted plugs, they can still be damaged and require replacement. 5amps so do i use a 2. Providing one extra 5A socket. He could then buy either a 3 A, 5 A or 13 A fuse to fit inside the plug. Most desktop PC's will not need higher than a 5A fuse. Don't appear to have any 10A fuses lying around or in the plugs I could do without. There are only two "standard" values - 3A and 13A, though 5A is also common, and other values exist. Which is what I'm going to try, unless anyone thinks it inadvisable? Frankly I didn't know 7A plug fuses were generally available, so there you go. 5 volts into a device that expects 5 volts is a Bad Thing and could have damaged the electronics inside. 6 out of 5 stars 4 £7. Is it safe to replace the former with the latter. Copper Plug 100- 250V 13A USA EU to UK Plug with Fuse, US $ 0. If you don't want to use 13A fused plugs and sockets, use the old style 5A or 15A round 3-pin plugs and sockets. A common UK plug is generally fitted with a 3A or 13A fuse. Find out what the conductor size of the cable is and fuse it to suit. Is this the show more Sounds trivial, but the fuse has blown on my XBox and everywhere is shut. So, yes, you can use a 3-A fuse in a plug, providing it matches the rating of the appliance it is intended to protect. Shop our inventory of Fuse Holders and Fuse Blocks online. I have a vacuum cleaner, which I wish to add a switch to, so that I can leave it plugged in all the time and use the switch to turn it on and off. In this case, if the appliance is less than 700W it should be changed to a 3A, or if it's less than 1200W it should be changed to a 5A. The 13A fuse in place of a 10A fuse wouldn't directly cause any problem - but then, if there's a problem with the appliance you're using, or if you plug in too many things and the current goes over 10A but under 13A, then under the new fuse the extension lead will keep working whereas the old fuse would have blown. To be clear, the plug of the wall cord has "13A - 250V" imprinted on it, then when I checked the fuse inside, that too was indeed a 13A fuse. The problem last night was that it was blowing fuses as soon as the mount started to slew to it's target, not the 5A fuses in the fuse box, but the 5A fuse in the cigarette adapter plug, now upon checking some of these fuses may have been 3. Choosing a fuse: Cartridge fuses come in a number of standard ratings. This is how we get to our 700W conclusion threshold. It's true that you can't get as much power through a single US plug as you can through a UK 13A plug, but that's because the voltage is higher. 54 / Piece, Guangdong, China, OEM, JHD07. Manufactured in either Nylon or Nylon/Urea versions, these durable plugs are designed for ease of use. Replacement fuses for UK 13A plug tops and also used in fused spur outlets. Fit a 3A fuse. Find out what the conductor size of the cable is and fuse it to suit. If 13A is the maximum allowable, then it could well be the case that the normal operation of your heater is > 5A, which would blow your 5A fuse immediately. As for which fuse to use, that very much depends on the appliance, you might only need a 5 amp fuse to power something that only needs 1kW, or a three amp fuse for. So there are many ways to skin the cat but you must always have an RCD in line, metal and liquid don't mix. The QBT-18 is a German made industrial grade fuse that has been cryogenically treated for 36 hours and then run in using Telos's in-house designed QBT burn-in machine for 18 hours. Source from Dongguan Tianrui Electronic Co. The general consensus is that a 13A fuse should only be used for very high drain devices and that for a laptop a 5A should suffice. 16A, always round up. 5 so use a 13A (brown) fuse A 20W table lamp is 20/240=0. I can only assume the plug is in some way damaged as this is the only reason I can think to change it. Try Prime Nartel® 20 x Mixed Electrical Ceramic Household Domestic Mains Plug Top Fuses 3A 5A 13A BS1362. The standard 13A plug was designed in conjunction with the (240V) Ring Main system, which has a 32A fuse, feeding several outlets (at least five or six twin outlets). Most lighting is protected by a 5amp fuse, which is a direct replacement (size wise) for a 13amp fuse in a 13amp plug, don't think you'll find many plugs that have a 1amp fuse fitting, although you could possibly squeeze the fuse holder prongs together for a 1amp to be used, if you really must. The sizes most commonly used are 3A, 5A, and 13A. Can someone settle an argument. Buy PRO ELEC - 13A UK Mains Plug, 13A Fuse, White (Box of 20) at CPC Farnell. Yes but there is a catch you cannot use these glass fuses in a plug top you have to use the same type of fuse and these are rated as 1,2,3,5,10,13 amps but most common fuses used are 3 and 13 amps in a domestic property the 1,2,5,10 are more common in a worplace So Kettle ,toaster,washing machine, would be 13 amps. Mains plug fuses use sand filled ceramic cartridges for extra breaking capacity. So there are many ways to skin the cat but you must always have an RCD in line, metal and liquid don't mix. I have read that you can use up to 130 amps on a standard household plug, but that's not working for me. 0 Mtrs, 13A Fuse - 10A IEC. Yes, the fuse type must be BS 646, I've added that to the article. Free delivery on eligible orders. When running an immersion heater (and some other stuff) from a 13amp plug, ive found that the contacts that hold the fuse in some) plugs melt before the fuse blows! I know running immersion heaters off plugs isnt normal behavior, but its made me consider how safe some plugs really are. 0 out of 5 stars 1. 5mm cable has a rating of 27A, generally if it's a spur inside the house it will be able to supply a full 26A, if it's in the garage or supplying a piece of fixed equipment or has more than one spur daisy chained. It is definitly the fuse as I put a new 5A fuse in the lead and it worked, again for one time only. As for which fuse to use, that very much depends on the appliance, you might only need a 5 amp fuse to power something that only needs 1kW, or a three amp fuse for. I can only assume the plug is in some way damaged as this is the only reason I can think to change it. The correct fuse is the one that matches the current rating of the lead. The plug is shaped in such a way that can be carried easily from room to room, wall unit to wall unit. • Use ordering number (see page 6 for details) Packaging prefixes • Blank (10 parts in a plastic bag) • BK- (100 parts in a plastic bag) • BK1- (1000 parts in plastic bag and box) TDC180 1/4" x 1. if you put a 13A fuse in the device might take upto 13A before the fuse blows and more than likely you'll fry it. What AMP fuse for a 1200W PSU? Fitted UK 3 Pin mains plug moulded with 5a fuse. Was in communication with a seller of 13A IEC mains cables today, and he reckons if the amp has its own internal 6. Which is what I'm going to try, unless anyone thinks it inadvisable? Frankly I didn't know 7A plug fuses were generally available, so there you go. Mains plug fuses use sand filled ceramic cartridges for extra breaking capacity. USE: T2A/250V. 5mm cable to a standard plug. An equipment with 700W ability consumption can take a current of 700W/230V which is 3A. com - pedal knobs,knob pedal,knobs for potentiometer,lamp,lamp lamp,lamp light. You would normally put a 3A fuse in a 13A plug for a light because the cable supplying it is quite thin and the only other protection would be a 32A fuse/MCB in the consumer unit. Why does my tv have a 10amp fuse in the mains plug? Hi, does anyone know why my KDL-40NX713 Bravia tv has a 10amp fuse in the mains plug? For the current that the tv draws a 1amp would be sufficient, but realistically a 3amp or 5amp would seem to be reasonable. Time-Delay Plug Base Fuses Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges, such as during equipment start- up. Having been using 13A plugs for high power applications for years I can confirm that 13A fused do in fact fail quite regularly when run at full current. Now the fuse in the power cord plug (which was supplied with the amp head) has a standard 3A fuse in it. Extensive Range of Electrical Plug Tops Ask about our competitive prices for bulk orders of electrical plug tops, including our standard MK safety 13A electrical plug tops (white), fused and Timeguard plug-in range, as for 13A socket. Another standardised adaptor would be required to convert the 13A plug of new equipment to the conventional 5A socket outlets many of us already have at home. I would not continue to use the shredder with a 13A fuse unless this was specified as correct. So I would swap the 13A fuse anyway for a 5A then you can use either lead in either device. Plugs are often made with a little window so you can turn them over and see the colour of the cartridge without unscrewing the plug. Mains plug fuses use sand filled ceramic cartridges for extra breaking capacity. In electrical appliances up to 700w, you need to use a 3A fuse. 2kw motor, it draws around 5A so a 5A fuse could easily blow especially on a long cycle so they stick a 13A in, bit overkill isnt it Why cant you get 7A fuses or 10A fuses If your maching developed a small issue and stated drawing twice the current the fuse wouldnt blow So whats the difference sticking a 13A fuse in for something that has a 5A fitted normally and draws 4A Fook all thats what. Smaller fuses can be used for low-power equipment, and common fuse sizes in use are 3A and 5A. A BS1363 plug with its cover removed. For technical details please see the PDF data sheet QuickTest QT1 and QT4 (opens in a new window). These fuses are opaque and often contain sand which is use to prevent a conductive film from forming on the fuse. If you were to put a 13A fuse instead of a 3A and the appliance was to develop a short circuit (extreme condition I know!), then 13A of current would be drawn through the cable causing it to heat up and possibly catch fire!. If in doubt don't fit a larger fuse. We strive to provide quality products at great prices and mix that with superb delivery speeds and customer service to make your online shopping experience an enjoyable one. also, to add, a spur socket doesn't have to have an inline 13A fuse, depending on the situation, a spur can provide up to 26A, as a 2. FREE next day delivery available, free collection in 5 minutes. 16A, always round up. 13A is the max voltage for domestic power sockets in the UK. 5A Brown 5Pce. The householder thinks it would be better for shops to sell the plugs without a fuse. 11 a 2 pin european 2 pin plug to be used in a UK 13A plug socket. Plugs for appliances rated between about 700 watts and 3000 watts (the maximum rating of a wall socket) should be fitted with a 13-amp fuse (coloured brown). Or you can ask your friend for help If you can not pay via paypal, we can cancel this transaction for you. TP&N Active Member. The following table gives examples of fuse ratings usually encountered for various items of equipment:. Sometimes you do find appliances (especially ovens) that draw a bit more than 13A and can therefore be a PITA to connect safely in the UK but it doesn't seem your case is one of them. IEC C14 - 13A Single Gang Trailing Socket Adaptor Lead Cable, ideal to convert power from an IEC C13 within a Server Rack, UPS, Computer or Stage Lighting. The way fuses work is there are a length of thin wire designed to break or trip at a certain power level i. Case proved I think for the fuse protecting the cable, if it is only rated 6 Amps then a 5A fuse should be fitted. I run my welder off a 3 pin plug. DimenSionS: 317 x 68 x 31mm SPeCiFiCation: max. The general consensus is that a 13A fuse should only be used for very high drain devices and that for a laptop a 5A should suffice. Thank you for submitting your requests. °C 200 200 200 200 200 Part Number X2E-108C X22-115C X2X-133C Functioning Temperature Tf. Rated 5 out of 5 by Debbie21 from Fuses Was great value great size pk Date published: 2019-09-09. The Grid Wiring Accessories Range has been developed to complement and integrate into our Screwless, Flat Plate and Metalclad ranges. fuse in device blows - fuse in plug does nothing Now lests see what happens with a 13a fuse A. AMR Audiophile Gold Hi-Fi Fuse 13A (UK Mains Plug) Priced at £15. USE: T2A/250V. If 13A worked, I would double check the actual fuse required and if it was 5A, I would buy some on Monday. Ubill Fuse 3a 5a 13a Thermal Fuse 10a 250v , Find Complete Details about Ubill Fuse 3a 5a 13a Thermal Fuse 10a 250v,Plug Fuse 250v 10a,Thermal Fuses 250v 3a,Fuse 3a 5a 13a from Fuses Supplier or Manufacturer-Dongguan Zhenghao Electronic Equipment Co. After some discussions and research, I determined that trying to pull 23a down through a standard 13a socket was a very bad idea. Basically so the lamp plugs don't have to be changed. If your PAT tester is capable of dual voltage measurement you can use this specialist adaptor to plug in a 230V mains lead into a 110V supply and initiate testing procedures. Our fuse box has RCD fuses fitted which is a legal requirement for homes as I understand. There are times when you need to replace a certain plug and here at Homebase our electrical plugs can be bought individually or in multipacks if it's more than one you're after. Plug Fuses (UK) Before we confuse you completely with the mathematics, let's look at some typical UK "230 volt 13 Amp plug" fuse ratings for appliances. Well, considering the maximum that can run through any plug socket with a 13A fuse, the most wattage you can get from a single socket is something like 240x13, which is over 3kW. Pack size: 5,10. Fuses are rated in amps. 15A BS 546 plug with a 5A BS 646 cartridge fuse. Plug top fuse links to IEC 60269-3, BS 88-3 and BS 1362 Intended primarily for use in UK domestic plugs to BS 1362 May also be installed in appropriate single phase installations with fault levels up to 6kA. Here's a counter argument I made a couple of years ago in response to those that say it's only there to protect the cable. With so many devices which are reliant on these products to function, replacement plugs and fuses are always good to have close to hand. The following table gives examples of fuse ratings usually encountered for various items of equipment:. Electricity Supply Fuse-Links. Its output is 2. The sizes most commonly used are 3A, 5A, and 13A. This cookies are strictly necessary and can not be turned off. Based in Dubai supplying UAE, Middle East & Asia. 3A, 5A and 13A are the only ones generally used. Fuse or circuit breakers, are devices that protect your electronic equipments(ee) from getting damaged by a surge that has a current more than what ee could. Subscription can be easily changed by contacting [email protected] 8m Cordset - A cordset consisting of a non-rewireable 13A sleeved pin mains plug and an IEC Javascript is currently disabled in your browser, please turn it on to avoid loss of functionality. I was just looking for a few spare plug leads for my NP8170 AC adapter and noticed that the plug that came with it has a 13A fuse in it. Replacing a fuse with a higher-amp fuse is a very bad idea and can lead to fires. Shop our inventory of Fuse Holders and Fuse Blocks online. The voltage of a fuse is a safety measure. Why Use 3-pin plugs for electrical safety? By Abhishek Jain (Mod) on October 25, 2015 with 79 Comments Putting a plug in a socket is something very basic thing which we all do; in fact it is a very much part of our daily and necessary routine in the modern times. The default value for a fuse is 13A. In this case, if the appliance is less than 700W it should be changed to a 3A, or if it’s less than 1200W it should be changed to a 5A. 5A 1A 2A 3A 4A 5A 6A 8A 10A 13A 15A 16A 20A 25A 30A More Buying Choices $7. If it's a standard BS1362 fuse (as fitted to BS1363 plugs), then it's designed to protect the power cord against major overloads, such as a short circuit in the appliance. Even if you do not want to register a PayPal account, you can still use your credit card to go through PayPal checkout process without any extra steps. My question is, do I need to wire the new oven through the 13A fused spur again or can I remove that entirely and safely wire the oven directly to the 45A fused cooker isolator/ switch. As for which fuse to use, that very much depends on the appliance, you might only need a 5 amp fuse to power something that only needs 1kW, or a three amp fuse for. To get these connections, electricians use two core wires and three core wires. Using a 16A appliance in a 13A socket? Class II and will come fitted with a 2. 2 layer height. Other fuses are available, chiefly 1A and 7A. LX8233 : 5V, 2. Buy Montpellier INT61T99-13A 59cm Induction Hob With Cable and 3 pin UK Plug - Black from Buy It Direct For help & advice 7 days a week 1520 932 633 Track Order. Note: Any severed plug must be destroyed to avoid a possible shock hazard should it be inserted into a 13A socket elsewhere. Fast Delivery at Electrical World. All plug fuses must comply to British Standard BS1362. One came with a 5A fuse and the other a 13A fuse, does anybody know which one belongs to which component and whether it makes a difference? I think maybe the 5A came with the monitor judging by how the cable is bent, also how long it is. 3mm D - RNTY51 from Alamy's library of millions of high resolution stock photos, illustrations and vectors. 5A or 16A plug that you can fit normal fuses to their 16 amp plugs of. I'm guessing that the lamp has blown and taken the fuse out with it? This happens a lot with the old incandescent lamps. My friend's dad suggests that you can use a 13A fuse in it's place but it "must be switched off after every use". After a fuse blows, it is supposed to block the current. Here's a counter argument I made a couple of years ago in response to those that say it's only there to protect the cable. This pack of fuses gives you 10 pieces of fuses that are 5A, 13A and 15A in specifications. Plugs are often made with a little window so you can turn them over and see the colour of the cartridge without unscrewing the plug. The correct fuse is the one that matches the current rating of the lead. 1A, 7A & 10A are not seen often today. Do not use glass fuses in mains plugs, these don't have the breaking capacity sometimes required. I went to set it back up today and I found I had 2 different plug attachments, one had a 3 amp fuse and the other had a 5 ampère fuse. BS 1362, the British Standard for plug fuses, specifies a maximum power dissipation of one watt when carrying the rated current. Small box to tidy up mains plug fuses. 51 and view our range of Plug Top Fuses online today!. wine~o wrote:Yep5 Amp is the maximum rating of the plug itself, so you can install your own fuse, in the same way as a 13A plug can be fitted with a 3, 5 or 13A fuse. There are times when you need to replace a certain plug and here at Homebase our electrical plugs can be bought individually or in multipacks if it's more than one you're after. A 10A fuse would not be appropriate for any TV set unless the set were designed to consume a couple of kilowatts!. An appliance with 700W power consumption takes a current of 700W/230V which is 3A. If 13A is the maximum allowable, then it could well be the case that the normal operation of your heater is > 5A, which would blow your 5A fuse immediately. The fuse on a Dyson plug can be changed by using a small screwdirver to lever off the fuse cover. 2mt Y Splitter Lead, UK 13a Plug - 2x IEC C13 Female The UK plug to two IEC (C13) cable, more commonly known as a kettle lead splitter cable is used for powering a variety of electrical appliances such as PC base units, monitors, printers, photocopiers and a whole host of other equipment. FREE Shipping. There are the older screw in fuses that were a menace, simply because you could screw a 20 or 30-amp fuse into a 15-amp socket. Holds 3 rows of 7 fuses (Main ones being 13A, 5A and 3A). Replacing a fuse with a higher-amp fuse is a very bad idea and can lead to fires. Fabricated with industrial grade plastic, ideal for use with power tools and electrical appliances. Some are 3A some 5A. I have also got a lovely example of a mint looking glass fuse with the wire clearly intact, however it doesn't conduct electricity. These fuses are then treated by Synergistic Research with 2,000,000 volts of electricity, in a process they call "Quantum Tunneling". By using a fuse larger than rated, it means it will allow a larger current to pass through. The purpose of a UK plug fuse is to melt before the cable does, thus reducing the risk of fire. After some discussions and research, I determined that trying to pull 23a down through a standard 13a socket was a very bad idea. Fuse or circuit breakers, are devices that protect your electronic equipments(ee) from getting damaged by a surge that has a current more than what ee could. 13A fuse fitted. 54 / Piece, Guangdong, China, OEM, JHD07. 6 out of 5 stars 4 £7. Here's food for thought but albeit a bit OT, many manufacturers recommend a 13A fuse for appliances using the 3 pin IEC connector. It's not safe to operate a heater without the appropriate fuse. The blade fuse is a common type of automotive fuse that has come into use in the last 20-30 years. Afaict all BS546 fused plugs use BS646 fuses so there is nothing stopping someone fitting a 5A fuse to a 2A plug. Source from Dongguan Tianrui Electronic Co. There are only two "standard" values - 3A and 13A, though 5A is also common, and other values exist. on Alibaba. I have a serial light whose plug is not working. If the fuse in the plug of your extension cable keeps blowing, resist the temptation to fit a bolt or. Yes but there is a catch you cannot use these glass fuses in a plug top you have to use the same type of fuse and these are rated as 1,2,3,5,10,13 amps but most common fuses used are 3 and 13 amps in a domestic property the 1,2,5,10 are more common in a worplace So Kettle ,toaster,washing machine, would be 13 amps. It can be used as a Coupler or Power Output to provide power to any 13 Amp Plug Device. I have spare plugs of 5A 250v. It has a 13A flat pin socket on the front, so that the original socket can still be used. If new fuse blows again, the last appliance connected may be faulty or you have exceeded the maximum total load of 13 Amp (3250 watts). 13A Plug Top with 5A Fuse - White (Screw Cord Grip) SN1381 Summary Carton Dimensions Fitting Images Warranty misc Wiring Accessories. Connector: All our power supplies have a connector that is standard for a 12V DC device. I can't see any problem with this but it is an unusual request that I have not been asked before. Can be changed to higher rated fuse Ordered the OCUK 13A plug as it has a. Also, the RMS voltage of mains in the UK is typically on the low side of 230V, not 240V, so your 5A is nearer 1. Vde To Bs Adapter Plug With Fuse 3a 5a Bs5733 Uk Travel Plug , Find Complete Details about Vde To Bs Adapter Plug With Fuse 3a 5a Bs5733 Uk Travel Plug,Eu To Uk Plug Adaptor,Multi Plug Adapter,Bs5733 Uk Travel Plug from Plugs & Sockets Supplier or Manufacturer-Shenzhen Boxin Technology Co. There used to be 10 amp fuses in 13 amp plugs to BS1363 in the UK , but nowadays fuses tend to be 3 or 13 amp rated. 1KW; the 5 amp fuse will likely suffice, but you would find most similar power supplies will typically be provided with 13A fuses in the mains cable (if one is supplied). Fuses are rated in amps. This is how we get to our 700W conclusion threshold. Competitive prices from the leading 125V 3A Cartridge Fuses distributor. If the mains plug contains a fuse, this should have a value of 5A. 00 The electrical mains power supply is the “fuel” that feeds every audio or visual system. Even though Shopping clothes Nilight GA0004 5Pack 12AWG Inline Wiring Harness 12 Gauge ATC/ATO Automotive Holder with 30A Fuse Blade Standard Plug Socket-5 Pack, 2 Years Warranty can be very convenient and a great way to save your time, ensure that any clothes you purchase could be returned if they don't fit or are not what you desired. If the fuse in the plug of your extension cable keeps blowing, resist the temptation to fit a bolt or. In the old days we had 2A, 5A and 15A but no 3A rated plugs. I have a vacuum cleaner, which I wish to add a switch to, so that I can leave it plugged in all the time and use the switch to turn it on and off. It would probably work if you plug it in to a normal socket but you might find that you need to replace the 13A fuse every now and then. R55 R56 Cigarette lighter and charging sockets Fuse # 42. Today I received a replacement charger for my laptop as the old one had been broken, it did not come with the plug attachment. As I said the other day I use an older 3-pin with the solid brass pins rather than one of the new 'safety' plugs with the plastic shrouded pins. Is this legal? I was going to cut the plugtop off and replace it with a standard UK plug, fused at 3A. For safety, Hong Kong users of Mainland appliances must have their plug replaced with a BS1363 one, fitted with a suitably rated (3A, 5A, 13A) BS1362 fuse. My friend's dad suggests that you can use a 13A fuse in it's place but it "must be switched off after every use". Plug in appliances one by one and check operation. Which is what I'm going to try, unless anyone thinks it inadvisable? Frankly I didn't know 7A plug fuses were generally available, so there you go. Source from Shenzhen Slinya Electronics Co. This is quite acceptable. A 5A fuse is fitted which applies to the 5A outlet only - the 13A outlet is directly connected to the pins. 5mm rated at 3 amp but min cable allowed is 0. You can never apply a fuse whose max voltage rating is smaller than the application voltage. So, yes, you can use a 3-A fuse in a plug, providing it matches the rating of the appliance it is intended to protect. 3 x 25mm, Speed F TDC180-13A or other Cartridge Fuses online from RS for next day delivery on your order plus great service and a great price from the largest electronics components. You can use an adapter (2 pin to 3 pin) to allow a 2 pin plug (found on electric toothbrushes) to connect to the 3 pin mains power supply. I will check and see if any of the other wires from j115 are going to higher rated fuses. It provides you with ample opportunities to protect your home or office's electrical circuit from excessive current. If the bulb blowing wasn't the cause of the fuse to blow, I would (as has been said) NOT replace it with a fuse of a higher rating - even as a temp measure. 9 out of 5 by 25. All screws from the single main 'keep the top on' central one down to the small 'stick the stripped earth wire under this and tighten it up' one can be done with a single PH screwdriver. 25mm (1") mains fuses for use in UK domestic 13A type plugs. hi there,I am making a power station for my mount and other things and was wondering what fuse i should use inline for the mount which is a heq5pro and is pulling about 2. So there are many ways to skin the cat but you must always have an RCD in line, metal and liquid don't mix. Yueqing Daier Electron Store has All Kinds of 100PCS DS-315 10mm ON-(OFF) momentary 0. I'm looking for the values of breakers and fuses to protect a 2. The plug got very hot after 3 minutes. The default value for a fuse is 13A. Counterfeit fuses are not filled in this way. Output DC=10. A fuse always produce heat and so a plug is always placed in free air to keep it cool. 13A Cartridge Fuses at Farnell. Check our stock now!. Metaphor electrical safety. The rating and "BS1362" should be explicitly marked on such fuses. If the cable is rated 5A then putting a 13A fuse in is not a good idea. The standard 13A plug was designed in conjunction with the (240V) Ring Main system, which has a 32A fuse, feeding several outlets (at least five or six twin outlets). This seems to be a fairly useless idea, since you could only use the 5A adaptor while the wired appliance was also powered. A TV might be 5A (black). The general consensus is that a 13A fuse should only be used for very high drain devices and that for a laptop a 5A should suffice. Cablesgo provides United Kingdom Power Cord and Power Supply Cord Sets 3A,5A,13A Fuse 250V BS 1363A AC Type G Plug products and UK plug,socket standard approvals, production drawings and technical support,Buying UK molded plug power cord , contact Cablesgo, China well-known power cord manufacturer. This is why I pose the question, I don't want to under or overload, I want to get the right one. Trailing sockets suitable for use in work environments. The listed prices are for one plug (or Fuse) only. 3-Pin Fused UK Mains Plugs - Various Options AVSL A range of 3-pin UK mains plugs in black or white. Browse a wide range of RS PRO Fuses, Sockets & Circuit Breakers. Best Answer: None. 5mm cable to a standard plug. Fuses for standard 13A plugs, need to comply with BS1362, and are available in the following sizes: 1A 2A 3A 5A 7A 10A 13A. Internally, all of the contacts and connections are on a printed circuit board. Sometimes you do find appliances (especially ovens) that draw a bit more than 13A and can therefore be a PITA to connect safely in the UK but it doesn't seem your case is one of them. The fuse breaks the circuit if a fault in an appliance causes too much current flow. our oven just broke, and it's plugged in via a 13A plug. Here's a counter argument I made a couple of years ago in response to those that say it's only there to protect the cable. One can see that a 3A or a 5A fuse would blow constantly if used in the plug for this iron leading us to choose a 13A fuse. Similar to wall switches, there are different types of Plug Sockets based on pin type such as two-pin plugs and three-pin plugs where the 3rd pin is for Earth Wire. Another standardised adaptor would be required to convert the 13A plug of new equipment to the conventional 5A socket outlets many of us already have at home. Holds 3 rows of 7 fuses (Main ones being 13A, 5A and 3A). I've replaced the cooker isolator / switch with a new one. Just because it says 13A on the plug doesn't mean it has to have a 13A fuse in! The plugs that we use on a day-to-day basis are BS1363 - that is they conform to the British Standard 1363, which first came into being in 1947 and has been updated a few times since. Although adaptors can be used, it is safer and cheaper to replace the plug. The way fuses work is there are a length of thin wire designed to break or trip at a certain power level i. 07 / Piece, Guangdong, China, Tianrui, BS1362. The mistake people make is using 13A flex between the supply and the fuse forgetting the fuse only protects downstream. Using 13a fuse for 5a plug My kenwood fan assisted oven is not working the fan is still going a fuse blew in the circuit box everything else is working except my fan assisted ov Can you replace a 15 amp fuse in your car with a 20 amp fuse for a cigarette lighter it keeps blowing the 15 amp?. 3A slow-blow fuse, then I should be using a 7A plug fuse with a 13A-rated IEC cable. 13A Plug Top with 5A Fuse - White (Screw Cord Grip) SN1381 Summary Carton Dimensions Fitting Images Warranty misc Wiring Accessories. eg 1000w appliance divided by 240 = 4. When choosing the right cartridge fuse for your application, you should pick a fuse that has a current rating that is slightly higher than what the device needs. Other fuses are available, chiefly 1A and 7A. i notice hifi mains leads come with 13a but my cd player mains lead did not come with a 13a one. Manufactured in either Nylon or Nylon/Urea versions, these durable plugs are designed for ease of use. What is HBC? HBC stands for high breaking current and refers to the maximum current that the fuse can handle without breaking. Now the fuse in the power cord plug (which was supplied with the amp head) has a standard 3A fuse in it. Gets them out of the normally oversized blister packs and stops them rolling around if you keep them loose in your man draw! Print with bottom of box and top of lid on bed so no need for support. As for the cause I realy dont know. I have a 16awg 13A 3pin plug to IEC-C13 socket but is it safe to use as the psu requires 15A? I also have a cheapo travellers universal adapter (13A fuse) that I can plug the 14awg 16A eu cable into but. The three main fuses used in the UK are 3A(red), 5A(black) and 13A(brown) although fuses of many different ratings can be found. In the old days we had 2A, 5A and 15A but no 3A rated plugs. Best Answer: None. If you use a 13amp 240v fuse in a 12v system will it blow when a 12v appliance drawing more than 156w (ie 12v x 13amps) is connected to it or does it require a 12v appliance to draw more than 3120w (ie 240v x 13amps) before it will blow. A fault in an appliance or even a partial short at the cable entry can produce a load which will not blow a 32A fuse but fry the lead and set fire to the carpet etc. A UK Government warning explains that counterfeit fuses can explode when they blow! Watch this video to see what happens to a counterfeit fuse when the flex connected to the plug is short circuited. Here’s an example: Say you bought a cold cathode kit for each side of the dash (2 Transformers), 5 superflux LED’s for your vents, and a 4. Is this legal? I was going to cut the plugtop off and replace it with a standard UK plug, fused at 3A. For cart and order processing 2 cookies will be stored. 5a, should be fine. Free delivery on eligible orders. If Possible, Don’t Use a Block Adaptor but a Multiway Bar Extension Lead – many of the block adaptors (those blocks of plastic with many sockets on them) are not very safe, do not have a fuse, and are not recommended to be used. It can be used as a Coupler or Power Output to provide power to any 13 Amp Plug Device. A good rule of thumb is to replace a fuse with a fuse of the same rating. I have a light spuring off a plug socket (via a fuse). WARRANTY WORK. After a fuse blows, it is supposed to block the current. • Use ordering number (see page 6 for details) Packaging prefixes • Blank (10 parts in a plastic bag) • BK- (100 parts in a plastic bag) • BK1- (1000 parts in plastic bag and box) TDC180 1/4" x 1. In plugs fuses are usually 3A (red), 5A (black), or 13A (brown). Check our stock now!. The original heater I tried was 5. 5A Cigarette Lighter Socket 240V Mains Plug to DC 12V Car Charger Power Adapter. We believe in helping you find the product that is right for you. The load on a circuit does not dictate the fuse, rather the cable and the fuse dictates the load. Short circuit, overloading or device failure are the prime reasons for excessive current. But, if the voltage is too high, there may be some current flowing through parasitic capacitance. The german plugs don't have a fuse at all and I'm 100% sure that the KPA has some fuses internal (besides: until a 5A fuse blows the KPA's internal fuse would have blown 10times) - so I'd say: just use the 13A cable. 5 So what is the fuse? How do u no which is which? Please explain, I need to no how to do a sheet on them. a short circuit in the power supply causing it to draw 2000W of power without the fuse even noticing. Maximum current for a unit supplied from a 13A socket, taking supply voltages into account.